Item | Value |
Operating speed | 1mm~500mm/s(Related with actuator forms) |
Operating frequency | Mechanical 60 cycles/min; electrical 25 cycles/min |
Insulation resistance | ≥100mΩ(500VDC) |
Contact resistance |
OF>0.75N:≤30mΩ(see note)
OF≤0.75N : ≤50mΩ(see note) KW10-D,E,Ftype:≤100mΩ (seende) |
(Test voltage) Between terminals of the same polarity | AC600V , 50/60Hz , 1min |
(Test voltage) Between current-carrying metal parts and
ground (case),and between each terminal and non-current-carrying metal parts |
AC1000V , 50/60Hz , 1min |
Vibration resistance | 10-55Hz , 1.5mm Double amplitude |
Shock resistance | Malfunction : 300m/s 2 (approx.30G)max |
Life |
Mechanical ≥ 1,000,000 cycles
Electrical≥10,000 cycles |
Weight | Approx.0.6g(No lever) |
Safety approvals | UL ,CUL ,TUV, ENEC, DEMKO, CE ,EK CQC |