Application:
Time relay can be widely used in machinery and equipment needing self-control of high precision and reliability. It is characterisitic of small size, light weight, compact strucure, high dependable and efficient, long life, ect
|
Classification
|
|
Multi Range Timer
|
Multi Range Timer
|
Multi Range Timer
|
|
Specification Model
|
|
H3CR-A8
|
H3CA-A
|
H3CA-8
|
|
Dimension
|
|
48H × 48W × 81.6D
|
48H × 48W × 81.6D
|
48H × 48W × 81.6D
|
|
Mounting & Socket
|
Surface(-N)
|
PS-08 PF083A
|
PF113A(E)
|
PS-08 PF083A
|
|
Flush(-Y)
|
US-08 P3G-08
|
US-11
|
US-08 P3G-08
|
|
Full Timing Range
|
|
0.5SEC~300HRS
|
0.1SEC~9990HRS
|
0.1SEC~9990HRS
|
|
Rated Voltage (V)
|
|
AC: 24,110~240(50/60Hz)
|
AC: 24~240(50/60Hz)
|
AC: 24,110, 220 (50/60Hz)
|
|
|
DC: 12,24~240(50/60Hz)
|
DC: 24~240(50/60Hz)
|
DC: 24,48(50/60Hz)
|
|
Indicator Operating
|
|
Time Operating Flicker
|
LCD
|
LCD
|
|
O/P Contact
|
Model
|
H3CR-A8
|
H3CA-A
|
H3CA-8
|
|
Time Limit 1C
|
|
5A
|
|
|
Time Limit 2C
|
5A(AC250)
|
|
5A
|
|
Instantaneous 1C
|
|
|
|
|
Life
|
Mechanical
|
107 Times
|
107 Times
|
107 Times
|
|
Electrical
|
105 Times
|
105 Times
|
105 Times
|
|
Accuracy
|
Repeat Error
|
±2% max
|
±2% max
|
±2% max
|
|
Setting Error
|
±5% max
|
±5% max
|
±5% max
|
|
Voltage Error
|
±5% max
|
±5% max
|
±5% max
|
|
Temp Error
|
±2% max
|
±2% max
|
±2% max
|
|
Reset Time
|
|
0.5 sec max
|
0.5 sec max
|
0.5 sec max
|
|
Consumed Power
|
|
100~240VAC:10VA 12VDC,24~240VDC:1.5W
|
100~240VAC:10VA 12VDC,24~240VDC:1.5W
|
100~240VAC:10VA 12VDC,24~240VDC:1.5W
|
|
Ambient temperature
|
|
-10oC~+55oC
|
-10oC~+55oC
|
-10oC~+55oC
|
|
Ambient Huminity
|
|
35~85% RH
|
35~85% RH
|
35~85% RH
|
|
Weight
|
|
100g
|
100g
|
100g
|