Touch Screen NIBP Simulator Dynamic Bp Simulation NIBP Monitor

Model NO.
MCS0397
Storage Temperature
-20 Centigrade to +65 Centigrade
Power
100-240 V AC 50/60 Hz,60 Va
Display
65K Colors 4.3 Inch TFT Display, Brightness Can Be
Size
27 Cm X 26.5 Cm X 13.2 Cm
Transport Package
Carton
Specification
3.5kg
Trademark
MeCan
Origin
China
Production Capacity
500pieces/Year
Reference Price
$ 675.00 - 844.20

Product Description

Touch Screen NIBP Simulator Dynamic BP Simulation NIBP Monitor

Model:MCS0397
Touch Screen NIBP Simulator Dynamic Bp Simulation NIBP Monitor

Product Description

Specifications
dynamic blood pressure simulations, static pressure calibration, automated leak testing, and pressure relief valve testing.

Product overview
   It is a multi-purpose tester applied to the oscillometric Non-Invasive Blood Pressure (NIBP)Monitor. It can test the performance of multiform blood pressure monitor, provides dynamic blood pressure simulations, static pressure calibration, automated leak testing, and pressure relief valve testing.

Main features
1. 4.3" LCD display,interface is concision,operation is simple and convenient.
2. Provides pressure gauge testing,pressure leak testing,relief valve testing functions .
3. Build-in pump provides pressure source with leak and pressure relief tests  
4. NIBP simulations for both arm and wrist cuffs.
5. Provides adult,neonate, seven variations patients conditions,user-defined simulations.
6. Provides arrhythmias,respiratory artifact simulations.
7. Built-in air chamber to simulate adult and neonate cuff.

 

Main Parameters
Heart Rate for NIBP Simulations Heart Rate Accuracy:   ±1BPM
Patient Conditions:
Weak pulse,Tachycardia,Obese ,Geriatric: ±1% ±1BPM
Mild exercise:     ±1.5% ±1BPM
Strenuous exercise:    ±3% ±1BPM
Pressure measurement Units:      mmHg,kPa,cmH2O,inH2O,psi
Range:      0 mmHg-400 mmHg
Resolution: 1 mmHg,  0.1 kPa, 1 cmH2O,  1 inH2O,  0.1 psi 
Accuracy:   0 - 300 mmHg: ±0.5 % of reading ±1 mmHg           301 - 400 mmHg: ±2 % of reading 
 Pressure Generation Pressure Generator, Static Pressure Range: 50 mmHg-400 mmHg
Difference between target pressure and actual pressure : ±10 mmHg from 100-400 mmHg with a minimum volume of 300 cc
Internal leak rate: <2 mmHg per minute, with a minimum volume of 300 cc


Touch Screen NIBP Simulator Dynamic Bp Simulation NIBP Monitor Touch Screen NIBP Simulator Dynamic Bp Simulation NIBP Monitor Touch Screen NIBP Simulator Dynamic Bp Simulation NIBP Monitor

Company Profile

Touch Screen NIBP Simulator Dynamic Bp Simulation NIBP Monitor Touch Screen NIBP Simulator Dynamic Bp Simulation NIBP Monitor Touch Screen NIBP Simulator Dynamic Bp Simulation NIBP Monitor Touch Screen NIBP Simulator Dynamic Bp Simulation NIBP Monitor Touch Screen NIBP Simulator Dynamic Bp Simulation NIBP Monitor Touch Screen NIBP Simulator Dynamic Bp Simulation NIBP Monitor Touch Screen NIBP Simulator Dynamic Bp Simulation NIBP Monitor

 