Electrostatic Discharge (ESD) flooring is also known as anti-static flooring, comes with anti-static performance (static-dissipative or conductive), and protects electronics from damage caused by static electricity.
Technical data
| Item | Standard | Data | |
| Electrical Resistance(Ω) |
SJ/T11236-2023
EN1081 |
Conductive | Dissipative |
| 1.0x 10E4 - 1.0 x 10E6 ohms | 1.0 x 10E6 to 1.0 x 10E9 ohms | ||
| Dimensional Stability(%) |
ASTM F2199:09(2014)
ISO 23999-2023 |
0.05% | |
| Starting Voltage |
SJ/T 10694-2006
EN 1815 |
IVI < 100V
< 2KV |
|
| AATCC-134 | 50 V | 100 V | |
| Static Decay(s) | GJB3007A-2009 | ≤ 2 sec | |
|
Federal Test Method
1018 Method 4046 |
0.01 sec | 0.01 sec | |
| Wear Resistance(1000r) | EN 660-2 | Class P | |
| SJ/T11236-2023 | ≤ 0.020 g/cm2 | ||
| Fire Resistance | SJ/T11236-2023 | FV-0 | |
| GB8624-2012 | B1(B-s1, t0) | ||
| ASTM E648-17 | Class I | ||
| EN13501-1 | Bfl - s1 | ||
| Slip Resistance Wet | DIN 51130 | R9 | |
| Residual Indentation(mm) | GB/T4085-2015 | ≤ 0.15 ≤ IR ≤ 0.40mm | |
| ISO 24343-1:2012 | 0.03 | ||
| Color Fastness | ISO 105-B02 | ≥ 6 | |
| Chemical Products Resistance | EN ISO 26987: 2012 | OK | |
| Toxic Testing |
EN 71-3 |
OK | |
| TVOC After 28 Days(μg/m³) | ISO 16000-3 | < 10 μg/m³ | |