 Application of Fiber Glass covered flat square aluminum wire :
Application of Fiber Glass covered flat square aluminum wire :
 
 4. Self adhesive glass fiber wrapped wire:
4. Self adhesive glass fiber wrapped wire:
| Name | Insulation Thickness/mm | Deviation | Minimum Breakdown Voltage/V | 
| Fiberglass film Covered Wire | 0.2 | ±15% | 2500 | 
| 0.3 | -15% | ||
| 0.4 | 5000 | ||
| 0.5 | |||
| 0.6 | |||
| 0.7 | 6000 | ||
| 0.8 | |||
| 0.9 | 
| Bending | Rod Diameter | |
| Broad Side | ≤8.00 | 10*Broad Side Size | 
| Broad Side | >8.00 | 15*Broad Side Size | 
| Narrow Side | All specifications | 10*Narrow Side Size | 
 
 
 
| Code | SB | SBMB | SBQ | |
| Composition | Copper or aluminum, and Glass-fiber covered | Rectangular Copper, Glass-fiber and film covered | Copper or aluminum, Glass-fiber and enameled | |
| Characteristic | Excellent resistance to overload, good corona-proof and resistance to moisture. | |||
| Application | Large capacity motors and electrical equipments | |||
| Rectangular wire | Thickness(mm) | 0.900-10.000 | 1.000-6.000 | |
| Width(mm) | 2.000-22.000 | 2.000-16.500 | ||
| Round wire(mm) | Φ1.000-8.000 | Φ1.000-8.000 | ||
| Temp. index | 130 155 180 | |||
| Test | Flexibility and adhesion | |||
| Breakdown voltage | ||||
| Applicable specification | GB7672 IEC317 | |||
| Name | Fiber Glass Covered Wire (Double Layer) | |||
| Model | GLELB-40/155 | |||
| Diameter | 4mm*6mm | |||
| Standard | GB/T7672.3-2008 | |||
| Test Item | Unit | Technical Requirement | Test Result | |
| Appearance | Uniform color, no Impact of defects | Ok | ||
| Bare Conductor | a | mm | ±0.05 | 3.98 | 
| b | mm | ±0.05 | 5.98 | |
| Thickness of insulation film | mm | 0.32-0.40-0.48 | 0.41 | |
| resistance | Ω/m | ≤0.02785 | 0.02774 | |
| Elongation | ≥17 | 31% | ||
| adhesion | 10% No cracking | no cracking | ||
| Breakdown Voltage | V | 560V | 910,850,830,900 | |
| Bending test | a and b winding | 15b, 10a, no crack | ||
| package | Meet the export standards | Ok | ||
| Quality Control Result | Ok | |||
 FAQ
FAQ