| SPECIFICATION | |||
| OUTPUT | |||
| Model | SCP - 75 -1 2 | SCP - 75 -24 | |
| DC Voltage | 13.8 V | 27.6 V | |
| Rated Current | 5.4 A | 2.7 A | |
| Current Range | 0- 5.4 A | 0- 2.7 A | |
| Rated Power | 74.5 W | 74.5 W | |
| Ripple & Noise | 1 2 0mVp-p | 2 00mVp-p | |
| Voltage Adj. Range | +15,-5% | +15,-5% | |
| Voltage Tolerance | ± 2 % | ±1% | |
| Inlet S tability | ± 1 % | ± 1 % | |
| Load S tability | ± 2 % | ± 1 % | |
| Setup, Rise, Hold Up Time | 5 00ms, 3 0ms/ 230 VAC 12 00ms, 3 0ms/ 115 VA C at full load | ||
| INPUT | |||
| Voltage Range | 85~ 264 VAC 120-370VDC | ||
| Frequency Range | 47-63Hz | ||
| AC Current | 0.7A/115V 0.5A/230VAC | ||
| Efficiency | 80% | 84% | |
| Inrush Current | Cold-start 45A | ||
| Leakage Current | < 2 mA/240VAC | ||
| PROTECTION | |||
| Over Load | 6.5A~8.7A rated output power | 3.2A~4.3A rated output power | |
| Protection type: hiccup mode,recovers automatically after fault condition is removed | |||
| Over Voltage | 16.6~19.3V | 33.1~38.5V | |
| Protection type: shut down o/p voltage, re-power on to recover | |||
| ENVIRONMENT | |||
| Working Temp., Humidity | - 2 0 ºC ~+60 ºC (Refer to output derating curve),20%~90%RH | ||
| Storage Temp., Humidity | - 4 0 ºC ~+85 ºC , 10%~95%RH | ||
| T em p. C oefficient | ±0.0 5 %/ ºC (0~ 45 ºC ) | ||
| Vibration | 10~500Hz,2G 10min,/1cycle,Period for 60min,Each along X.Y.Z axes | ||
| SAFETY | |||
| Withstand Voltage | I/P-O/P: 3 KVAC I/P-FG: 2 KVAC O/P-FG: 0.5KVAC | ||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | ||
| STANDARD | |||
| Safety Standard | UL60950-1,CCC,CE | ||
| EMC Standard | Design refer to EN55022(CLSPR22),EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 | ||
| OTHERS | |||
| D imension | 159*97*38 mm ( L*W*H) | ||
| Weight | 0. 5 Kg /pc 30pcs/carton | ||
 
 
 
 
 Low loss SCP-75 13.8Vdc 75w single output switching power supply with UPS function