1.High-powered microinverter for 1-in-1 with output power up to 500 VA.
2.With Reactive Power Control, compliant with EN 50549-1:2023, VDE-AR-N 4105:2023, VFR2023, etc.
3.Safer for rooftop solar stations with rapid shutdown compliance and isolated transformer.
4.Connected to one panel, flexible for various applications
5.Sub-1G wireless solution allows stable communication with Hoymiles gateway DTU.
| Microinverter-Integrated Solar Module | ||
| solar module | ||
| Electrical Characteristics (STC) | Maximum power - Pm (W) | 400 |
| Open circuit voltage - Voc (V) | 45.55 | |
| Short circuit current I sc (A) | 13.9 | |
| Maximum Power Voliage-Vm (V) | 38.38 | |
| Maximum Power Currenblm (A) | 13.03 | |
| Module Efficiency-n (%) | 21.3 | |
| Dimensions | 2092x1134x35mm (LxWxH) | |
| Weight | 25kg | |
| Front Glass | 3.2mm ( Anti-Reflflection Coaling, High Transmission, Low Iron, Tempered Glass | |
| Frame | Anodized Aluminium Alloy | |
| Mechanical Parameters | Cells | Mono-crystalline solar cell |
| Cell Orientation | 132 (6*22) | |
| Junction Box | IP68 Rated | |
| Cable | 4mm2, +500mm/-1 OOOmm(Venical), +250mm/-150mm (Horizonial) | |
| Packaging mode | 31 pcs/ box; 620pcs/ 40' HQ | |
| NOCT | 45°C(±2°C) | |
| Temperature Parameters | Temperature Coefficient of Voc | -0.28%/ .. |
| Temperature Coefficient of Isc | 0.048%/°C | |
| Temperature Coefficient of Pm | -0.35%/°C | |
| Maximum Sysiem VoUage (V) | DC1000/1500 |
| Commonly used module power (W) | 400 | ||
| Commonly used module power (W) | Up to 500 (single panel) | ||
| Peak power MPPT voltage range (V) | 34-48 | ||
| Start-up voltage (V) | 22 | ||
| Operating voltage range (V) | 16-60 | ||
| Maximum input voltage (V) | 60 | ||
| Maximum input current (A) | 12.5 | ||
| Maximum input short-circuit current (A) | 15 | ||
| Maximum backfeed current to array (A) | 0 | ||
| Number of MPPTs | 1 | ||
| Number of inputs per MPPT | 1 | ||
| Rated output power (VA) | 400 | ||
| Rated output current (A) | 1.82@220 V 1.74@230 V 1.67@240 V | ||
| Nominal output voltage/range (V) | 220/180-275 230/180-275 240/180-275 | ||
| Nominal frequency/range (Hz) | 45-55 (under 50 Hz @ 220 V & 230 V) 55-65 (under 60 Hz @ 220 V & 230 V) | ||
| Power factor | > 0.99 default 0.8 leading...0.8 lagging | ||
| Output current harmonic distortion | <3% | ||
| Maximum units per branch | 12@220V 12@230V 12@240V | ||
| Peak microinverter efficiency | 96.70% | ||
| CEC weighted efficiency | 96.50% | ||
| Nominal MPPT efficiency | 99.80% | ||
| Night time power consumption(mW) | <50 | ||
| Ambient temperature range (°C) | -40 to +65 | ||
| Storage temperature range (°C) | -40 to +85 | ||
| Dimensions (W x h x d mm) | 182 x 164x29.5 | ||
| Weight (kg) | 1.98 | ||
| Enclosure rating | Outdoor NEMA6(IP67) | ||
| Cooling | Natural convection (no fans) | ||
| Pollution degree | PD3 | ||
| Ambient temperature range (°C) | -40 to +65 | ||
| Storage temperature range (°C) | -40 to +85 | ||
| Dimensions (W x h x d mm) | 182 x 164x29.5 | ||
| Weight (kg) | 1.98 | ||
| Enclosure rating | Outdoor NEMA6(IP67) | ||
| Cooling | Natural convection (no fans) | ||
| Pollution degree | PD3 | ||
Q1: How to choose a right system and products?