Electrical Characteristics | STC:AM1.5 1000W/m 2 25°C | NOCT:AM1.5 800W/m 2 20°C Im/s | Test uncertainty for Pmax: ±3% | |||||||
Module Type | LR4-60HPH-365M | LR4-60HPH-370M | LR4-60HPH-375M | LR4-60HPH-380M | LR4-60HPH-385M | |||||
Testing Condition | STC | NOCT | STC | NOCT | STC | NOCT | STC | NOCT | STC NOCT | |
Maximum Power (Pmax/W) | 365 | 274.2 | 370 | 277.9 | 375.0 | 281.7 | 380 | 285.5 | 385.0 | 289.2 |
Open Circuit Voltage (Voc/V) | 40.7 | 38.3 | 40.9 | 38.5 | 41.1 | 38.6 | 41.3 | 38.8 | 41.5 | 39.0 |
Short Circuit Current (Isc/A) | 11.43 | 9.27 | 11,52 | 9.34 | 11.60 | 9.41 | 11.69 | 9.48 | 11.77 | 9.54 |
Voltage at Maximum Power (Vmp/V) | 34.2 | 31.8 | 34.4 | 32.0 | 34.6 | 32.2 | 34.8 | 32.4 | 35.0 | 32.6 |
Current at Maximum Power (Imp/A) | 10.68 | 8.61 | 10.76 | 8.68 | 10.84 | 8.75 | 10.92 | 8.81 | 11.00 | 8.88 |
Module Efficiency (%) | 20.0 | 20.3 | 20.6 | 20.9 | 21.1 |
Operating Parameters | Mechanical Loading | |||||||||
Operational Temperature | -40°C~+85°C | Front Side Maximum Static Loading | 5400Pa | |||||||
Power Output Tolerance | 0-3% | Rear Side Maximum Static Loading | 2400Pa | |||||||
Voc and Isc Tolerance | ±3% | Hailstone Test | 25mm Hailstone at the speed of23m/s | |||||||
Maximum System Voltage | DC1500V(IEC) | |||||||||
Maximum Series Fuse Rating | 20A | |||||||||
Nominal Operating Cell Temperature | 45±2°C | Temperature Ratings (STC) | ||||||||
Protection Class | Class II | Temperature Coefficient of Isc | +0.050%/°C | |||||||
Fire Rating |
type 1 or 2
1 EC Class C |
Temperature Coefficient of Voc | -0.265%/°C | |||||||
Temperature Coefficient of Pmax | -0.340%/°C |